Ramon Pallàs-Areny

Orcid: 0000-0002-0430-5309

According to our database1, Ramon Pallàs-Areny authored at least 40 papers between 1992 and 2020.

Collaborative distances:
  • Dijkstra number2 of five.
  • Erdős number3 of five.

Awards

IEEE Fellow

IEEE Fellow 1998, "For contributions to medical and electronic instrumentation and biomedical sensors.".

Timeline

Legend:

Book 
In proceedings 
Article 
PhD thesis 
Dataset
Other 

Links

On csauthors.net:

Bibliography

2020
Comments on "A novel high input impedance front-end for capacitive biopotential measurement".
Medical Biol. Eng. Comput., 2020

2019
Cost-effective autonomous sensor for the long-term monitoring of water electrical conductivity of crop fields.
Comput. Electron. Agric., 2019

2018
Solar energy radiation measurement with a low-power solar energy harvester.
Comput. Electron. Agric., 2018

2017
A novel low-cost smart leaf wetness sensor.
Comput. Electron. Agric., 2017

2016
Letter to the Editor "On the Feasibility of Noncontact ECG Measurements".
IEEE Trans. Instrum. Meas., 2016

An algorithm for beat-to-beat heart rate detection from the BCG based on the continuous spline wavelet transform.
Biomed. Signal Process. Control., 2016

Direct Pulse Transit Time Measurement from an Electronic Weighing Scale.
Proceedings of the Computing in Cardiology, CinC 2016, Vancouver, 2016

A Novel Algorithm for Fast Ballistocardiogram Cycle Extraction in Ambulatory Scenarios.
Proceedings of the Computing in Cardiology, CinC 2016, Vancouver, 2016

Impact of the Mechanical Interface on BCG Signals obtained from Electronic Weighing Scales.
Proceedings of the Computing in Cardiology, CinC 2016, Vancouver, 2016

Enabling Atrial Fibrillation Detection Using a Weight Scale.
Proceedings of the Computing in Cardiology, CinC 2016, Vancouver, 2016

2015
Effects of stray capacitance to ground in three electrode monopolar needle bioimpedance measurements.
Proceedings of the 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2015

2014
Noise Reduction in AC-Coupled Amplifiers.
IEEE Trans. Instrum. Meas., 2014

Effects of Stray Capacitance to Ground in Bipolar Material Impedance Measurements Based on Direct-Contact Electrodes.
IEEE Trans. Instrum. Meas., 2014

2013
A Novel Method to Estimate Body Capacitance to Ground at Mid Frequencies.
IEEE Trans. Instrum. Meas., 2013

2012
On the Effect of Body Capacitance to Ground in Tetrapolar Bioimpedance Measurements.
IEEE Trans. Biomed. Eng., 2012

Multi-signal bathroom scale to assess long-term trends in cardiovascular parameters.
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2012

On time interval measurements using BCG.
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2012

2011
Can driven-right-leg circuits increase interference in ECG amplifiers?
Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011

Pulse arrival time estimation from the impedance plethysmogram obtained with a handheld device.
Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011

2009
Analysis of a Direct Interface Circuit for Capacitive Sensors.
IEEE Trans. Instrum. Meas., 2009

Fully Differential AC-Coupling Networks: A Comparative Study.
IEEE Trans. Instrum. Meas., 2009

2008
Heart Rate Detection From Plantar Bioimpedance Measurements.
IEEE Trans. Biomed. Eng., 2008

2007
Analysis of Power-Supply Interference Effects on Direct Sensor-to-Microcontroller Interfaces.
IEEE Trans. Instrum. Meas., 2007

Improved Fully Differential Analog Filters.
IEEE Trans. Instrum. Meas., 2007

Synchronous Demodulator for Autonomous Sensors.
IEEE Trans. Instrum. Meas., 2007

2006
A practical approach to electrode-skin impedance unbalance measurement.
IEEE Trans. Biomed. Eng., 2006

Novel indices of ventricular repolarization to screen post myocardial infarction patients.
Comput. Biol. Medicine, 2006

2005
Error analysis in two-terminal impedance measurements with residual correction.
IEEE Trans. Instrum. Meas., 2005

2004
A novel fully differential biopotential amplifier with DC suppression.
IEEE Trans. Biomed. Eng., 2004

2003
Correction to "Error analysis and reduction for a simple sensor-microcontroller interface".
IEEE Trans. Instrum. Meas., 2003

AC-coupled front-end for biopotential measurements.
IEEE Trans. Biomed. Eng., 2003

2002
Comments on "on resistor-induced thermal noise in linear circuits".
IEEE Trans. Instrum. Meas., 2002

Compensation of impedance meters, when using an external front-end amplifier.
IEEE Trans. Instrum. Meas., 2002

Analog signal processing in an AC electromagnetic flowmeter.
IEEE Trans. Instrum. Meas., 2002

2001
Error analysis and reduction for a simple sensor-microcontroller interface.
IEEE Trans. Instrum. Meas., 2001

A novel robust index to assess beat-to-beat variability in heart rate time-series analysis.
IEEE Trans. Biomed. Eng., 2001

2000
A comprehensive model for power line interference in biopotential measurements.
IEEE Trans. Instrum. Meas., 2000

1998
Subsurface resistivity measurements using square waveforms.
IEEE Trans. Instrum. Meas., 1998

The floating capacitor as a differential building block.
IEEE Trans. Instrum. Meas., 1998

1992
Walsh function current patterns and data synthesis for electrical impedance tomography.
IEEE Trans. Medical Imaging, 1992


  Loading...