Daniel R. Bednarek

According to our database1, Daniel R. Bednarek authored at least 42 papers between 2002 and 2023.

Collaborative distances:
  • Dijkstra number2 of four.
  • Erdős number3 of four.

Timeline

Legend:

Book 
In proceedings 
Article 
PhD thesis 
Dataset
Other 

Links

On csauthors.net:

Bibliography

2023
A Prototype Software System for Intra-procedural Staff Dose Monitoring and Virtual Reality Training for Fluoroscopically Guided Interventional Procedures.
J. Digit. Imaging, June, 2023

Comparison of pulsatile flow dynamics before and after endovascular intervention in 3D-printed patient-specific internal carotid artery aneurysm models using 1000 fps photon-counting detectors for Simultaneous Biplane High Speed Angiography (SB-HSA).
Proceedings of the Medical Imaging 2023: Biomedical Applications in Molecular, 2023

Determining 3D distributions of pulsatile blood flow using orthogonal Simultaneous Biplane High-Speed Angiography (SB-HSA) with 1000 fps CdTe photon counting detectors for 3D X-ray Particle Image Velocimetry (3D-XPIV) compared to results using Computational Fluid Dynamics (CFD).
Proceedings of the Medical Imaging 2023: Biomedical Applications in Molecular, 2023

Geometrically independent contrast dilution gradient (CDG) velocimetry using photon-counting 1000 fps High Speed Angiography (HSA) for 2D velocity distribution estimation.
Proceedings of the Medical Imaging 2023: Biomedical Applications in Molecular, 2023

Investigating angiographic injection parameters for cerebral aneurysm hemodynamic characterization using patient-specific simulated angiograms.
Proceedings of the Medical Imaging 2023: Biomedical Applications in Molecular, 2023

Multi-angled simultaneous biplane High-Speed Angiography (HSA) of patient-specific 3D-printed aneurysm phantoms using 1000 fps CdTe Photon-Counting Detectors (PCD's).
Proceedings of the Medical Imaging 2023: Biomedical Applications in Molecular, 2023

2022
Initial evaluation of 2D and 3D simulated high-speed 1000 fps vascular contrast-flow image sequences using computational fluid dynamics (CFD).
Proceedings of the Medical Imaging 2022: Biomedical Applications in Molecular, 2022

Derivation of vascular wall shear stress from 1000 fps high-speed angiography (HSA) velocity distributions.
Proceedings of the Medical Imaging 2022: Biomedical Applications in Molecular, 2022

Semi-automatic co-registration of 3D CFD vascular geometry to 1000 fps high-speed angiographic (HSA) projection images for flow determination comparisons.
Proceedings of the Medical Imaging 2022: Biomedical Applications in Molecular, 2022

Leveraging patient-specific simulated angiograms to characterize cerebral aneurysm hemodynamics using computational fluid dynamics.
Proceedings of the Medical Imaging 2022: Biomedical Applications in Molecular, 2022

2021
Characterization of velocity patterns produced by pulsatile and constant flows using 1000 fps high-speed angiography (HSA).
Proceedings of the Medical Imaging 2021: Biomedical Applications in Molecular, 2021

2020
Exploration of pathology-specific flow patterns utilizing high speed angiography at 1000 fps.
Proceedings of the Medical Imaging 2020: Biomedical Applications in Molecular, 2020

Image processing using Convolutional Neural Network (CNN) for Region of Interest (ROI) fluoroscopy.
Proceedings of the Medical Imaging 2020: Biomedical Applications in Molecular, 2020

Initial investigations of x-ray particle imaging velocimetry (X-PIV) in 3D printed phantoms using 1000 fps High-Speed Angiography (HSA).
Proceedings of the Medical Imaging 2020: Biomedical Applications in Molecular, 2020

Quantifying the effects of stenosis on blood flow using 1000 fps High-Speed Angiography (HSA).
Proceedings of the Medical Imaging 2020: Biomedical Applications in Molecular, 2020

2019
Rapid cone-beam computed tomography (CBCT) using an ultra-high frame rate imaging photon counting detector (PCD) with 100 μm resolution.
Proceedings of the Medical Imaging 2019: Biomedical Applications in Molecular, 2019

Rapid sequence angiography with a 3D printed aneurysm phantom and an ultra-high frame rate imaging photon counting detector (PCD).
Proceedings of the Medical Imaging 2019: Biomedical Applications in Molecular, 2019

Demonstration of improved image resolution for larger focal spot sizes by decreasing anode angles in clinical settings.
Proceedings of the Medical Imaging 2019: Biomedical Applications in Molecular, 2019

2018
Use of material decomposition in the context of neurovascular intervention using standard flat panel and a high-resolution CMOS detector.
Proceedings of the Medical Imaging 2018: Biomedical Applications in Molecular, 2018

A simulation platform using 3D printed neurovascular phantoms for clinical utility evaluation of new imaging technologies.
Proceedings of the Medical Imaging 2018: Biomedical Applications in Molecular, 2018

2017
Implementation of material decomposition using an EMCCD and CMOS-based micro-CT system.
Proceedings of the Medical Imaging 2017: Biomedical Applications in Molecular, 2017

Use of patient specific 3D printed neurovascular phantoms to evaluate the clinical utility of a high resolution x-ray imager.
Proceedings of the Medical Imaging 2017: Biomedical Applications in Molecular, 2017

2016
Investigation of signal thresholding to reduce the effects of instrument noise of an EMCCD based micro-CT system.
Proceedings of the Medical Imaging 2016: Biomedical Applications in Molecular, Structural, and Functional Imaging, San Diego, California, United States, 27 February, 2016

Sensitivity evaluation of DSA-based parametric imaging using Doppler ultrasound in neurovascular phantoms.
Proceedings of the Medical Imaging 2016: Biomedical Applications in Molecular, Structural, and Functional Imaging, San Diego, California, United States, 27 February, 2016

2015
Angiographic analysis for phantom simulations of endovascular aneurysm treatments with a new fully retrievable asymmetric flow diverter.
Proceedings of the Medical Imaging 2015: Biomedical Applications in Molecular, 2015

Initial testing of a 3D printed perfusion phantom using digital subtraction angiography.
Proceedings of the Medical Imaging 2015: Biomedical Applications in Molecular, 2015

Treatment planning for image-guided neuro-vascular interventions using patient-specific 3D printed phantoms.
Proceedings of the Medical Imaging 2015: Biomedical Applications in Molecular, 2015

Micro-computed tomography (CT) based assessment of dental regenerative therapy in the canine mandible model.
Proceedings of the Medical Imaging 2015: Biomedical Applications in Molecular, 2015

2012
A 2×2 array of EMCCD-based solid state x-ray detectors.
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2012

Implementation of digital multiplexing for high resolution x-ray detector arrays.
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2012

2011
Spatially different, real-time temporal filtering and dose reduction for dynamic image guidance during neurovascular interventions.
Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011

EMCCD-based high resolution dynamic x-ray detector for neurovascular interventions.
Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011

Image geometric corrections for a new EMCCD-based dual modular x-ray imager.
Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011

2008
Cone-Beam Micro-CT System Based on LabVIEW Software.
J. Digit. Imaging, 2008

Investigation of new flow modifying endovascular image-guided interventional (EIGI) techniques in patient-specific aneurysm phantoms (PSAPs) using optical imaging.
Proceedings of the Medical Imaging 2008: Visualization, 2008

Implementation of a high-sensitivity micro-angiographic fluoroscope (HS-MAF) for in-vivo endovascular image guided interventions (EIGI) and region-of-interest computed tomography (ROI-CT).
Proceedings of the Medical Imaging 2008: Visualization, 2008

2005
Artifact reduction in truncated CT using sinogram completion.
Proceedings of the Medical Imaging 2005: Image Processing, 2005

Microangiographic image-guided localization of a new asymmetric stent for treatment of cerebral aneurysms.
Proceedings of the Medical Imaging 2005: Visualization, 2005

2004
A computer-graphic display for real-time operator feedback during interventional x-ray procedures.
Proceedings of the Medical Imaging 2004: Visualization, 2004

2002
Determination of biplane geometry and centerline curvature in vascular imaging.
Proceedings of the Medical Imaging 2002: Image Processing, 2002

Reconstruction of asymmetric vessel lumen from two views.
Proceedings of the Medical Imaging 2002: Image Processing, 2002

Accuracy comparison of micro-angiographic detector and image intensifier for an interventional localization task.
Proceedings of the 2002 IEEE International Symposium on Biomedical Imaging, 2002


  Loading...