Xiao Liu

Orcid: 0000-0001-5514-021X

Affiliations:
  • University College London, Department of Electronic and Electrical Engineering, UK


According to our database1, Xiao Liu authored at least 29 papers between 2005 and 2018.

Collaborative distances:
  • Dijkstra number2 of five.
  • Erdős number3 of four.

Timeline

Legend:

Book 
In proceedings 
Article 
PhD thesis 
Dataset
Other 

Links

Online presence:

On csauthors.net:

Bibliography

2018
A Human-Machine Interface Using Electrical Impedance Tomography for Hand Prosthesis Control.
IEEE Trans. Biomed. Circuits Syst., 2018

Towards a High Accuracy Wearable Hand Gesture Recognition System Using EIT.
Proceedings of the IEEE International Symposium on Circuits and Systems, 2018

A Capacitance-to-Digits Readout Circuit for Integrated Humidity Sensors for Monitoring the In-Package Humidity of Ultra-Small Medical Implants.
Proceedings of the IEEE International Symposium on Circuits and Systems, 2018

Asymmetrical Sensing Configuration for Improved Sensitivity in Calorimetric High Flow Measurements in Constant Power Mode.
Proceedings of the 2018 IEEE SENSORS, New Delhi, India, October 28-31, 2018, 2018

2016
Advances in Scalable Implantable Systems for Neurostimulation Using Networked ASICs.
IEEE Des. Test, 2016

Design considerations and optimization of calorimetric flow sensor for respiratory monitoring.
Proceedings of the IEEE Biomedical Circuits and Systems Conference, 2016

2015
Introduction to the Special Issue on Biomedical and Bioelectronic Circuits for Enhanced Diagnosis and Therapy.
IEEE Trans. Circuits Syst. II Express Briefs, 2015

2013
Design of an implantable stimulator ASIC with self-adapting supply.
Proceedings of the 2013 IEEE International Symposium on Circuits and Systems (ISCAS2013), 2013

2012
A Compact Rail-to-Rail Class-AB CMOS Buffer With Slew-Rate Enhancement.
IEEE Trans. Circuits Syst. II Express Briefs, 2012

Active Books: The Design of an Implantable Stimulator That Minimizes Cable Count Using Integrated Circuits Very Close to Electrodes.
IEEE Trans. Biomed. Circuits Syst., 2012

An implantable 3-D vestibular stimulator with neural recording.
Proceedings of the 38th European Solid-State Circuit conference, 2012

2011
A CMOS Instrumentation Amplifier With 90-dB CMRR at 2-MHz Using Capacitive Neutralization: Analysis, Design Considerations, and Implementation.
IEEE Trans. Circuits Syst. I Regul. Pap., 2011

A Stimulator ASIC Featuring Versatile Management for Vestibular Prostheses.
IEEE Trans. Biomed. Circuits Syst., 2011

An Integrated Stimulator With DC-Isolation and Fine Current Control for Implanted Nerve Tripoles.
IEEE J. Solid State Circuits, 2011

A stimulator ASIC with capability of neural recording during inter-phase delay.
Proceedings of the 37th European Solid-State Circuits Conference, 2011

Realization of an active book for multichannel intrathecal root stimulation in spinal cord injury - Preliminary results.
Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011

2010
A current generator circuit for tripolar stimulation and insensitive to temperature and supply variations.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2010), May 30, 2010

A dual-mode neural stimulator capable of delivering constant current in current-mode and high stimulus charge in semi-voltage-mode.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2010), May 30, 2010

A DC-isolated fine-controlled neural stimulator.
Proceedings of the 36th European Solid-State Circuits Conference, 2010

2008
An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors.
IEEE Trans. Biomed. Circuits Syst., 2008

Platinum electrode noise in the ENG spectrum.
Medical Biol. Eng. Comput., 2008

A programmable ENG amplifier with passive EMG neutralization for FES applications.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2008), 2008

2007
A Safe Transmission Strategy for Power and Data Recovery in Biomedical Implanted Devices.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2007), 2007

A Fully Integrated Fail-safe Stimulator Output Stage Dedicated to FES Stimulation.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2007), 2007

A fail-safe ASIC for implantable neural stimulation.
Proceedings of the 33rd European Solid-State Circuits Conference, 2007

Recent advances in the design of implantable stimulator output stages.
Proceedings of the 18th European Conference on Circuit Theory and Design, 2007

2006
A stimulator output stage with capacitor reduction and failure-checking techniques.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2006), 2006

A Miniaturized, Power-Efficent Stimulator Output Stage Based on the Bridge Rectifier Circuit.
Proceedings of the IEEE Asia Pacific Conference on Circuits and Systems 2006, 2006

2005
Generation of balanced biphasic stimulus current with integrated blocking capacitor.
Proceedings of the 2005 European Conference on Circuit Theory and Design, 2005


  Loading...