Nick Donaldson

According to our database1, Nick Donaldson authored at least 76 papers between 1998 and 2023.

Collaborative distances:
  • Dijkstra number2 of five.
  • Erdős number3 of four.

Timeline

Legend:

Book 
In proceedings 
Article 
PhD thesis 
Dataset
Other 

Links

On csauthors.net:

Bibliography

2023
A Multielectrode Nerve Cuff for Chronic Velocity Selective Recording in a sheep model.
Proceedings of the 45th Annual International Conference of the IEEE Engineering in Medicine & Biology Society, 2023

2022
The Design of a Low Noise, Multi-Channel Recording System for Use in Implanted Peripheral Nerve Interfaces.
Sensors, 2022

2021
Urinary Bladder Innervation within the Sacral Roots of a Sheep.
Proceedings of the 10th International IEEE/EMBS Conference on Neural Engineering, 2021

Adapting the Finetech-Brindley Sacral Anterior Root Stimulator for Bioelectronic Medicine<sup>*</sup>.
Proceedings of the 43rd Annual International Conference of the IEEE Engineering in Medicine & Biology Society, 2021

2020
The Neural Engine: A Reprogrammable Low Power Platform for Closed-Loop Optogenetics.
IEEE Trans. Biomed. Eng., 2020

The Effects of the Presence of Multiple Conduction Velocities in the Analysis of Electrically-Evoked Compound Action Potentials (eCAPs).
Proceedings of the 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society, 2020

Selective Recording of Urinary Bladder Fullness from the Extradural Sacral Roots<sup>*</sup>.
Proceedings of the 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society, 2020

2019
An ASIC for Recording and Stimulation in Stacked Microchannel Neural Interfaces.
IEEE Trans. Biomed. Circuits Syst., 2019

A Bayesian Demonstration of Reliability for Encapsulated Implanted Electronics.
Proceedings of the 2019 9th International IEEE/EMBS Conference on Neural Engineering (NER), 2019

2018
A Capacitance-to-Digits Readout Circuit for Integrated Humidity Sensors for Monitoring the In-Package Humidity of Ultra-Small Medical Implants.
Proceedings of the IEEE International Symposium on Circuits and Systems, 2018

A MicroChannel Neural Interface ASIC.
Proceedings of the IEEE International Symposium on Circuits and Systems, 2018

Integrated Devices for Micro-Package Integrity Monitoring in mm-Scale Neural Implants.
Proceedings of the 2018 IEEE Biomedical Circuits and Systems Conference, 2018

2017
Four-Wire Interface ASIC for a Multi-Implant Link.
IEEE Trans. Circuits Syst. I Regul. Pap., 2017

An Integrated Passive Phase-Shift Keying Modulator for Biomedical Implants With Power Telemetry Over a Single Inductive Link.
IEEE Trans. Biomed. Circuits Syst., 2017

An implantable ENG detector with in-system velocity selective recording (VSR) capability.
Medical Biol. Eng. Comput., 2017

2016
Advances in Scalable Implantable Systems for Neurostimulation Using Networked ASICs.
IEEE Des. Test, 2016

Live demonstration: An implantable wireless multi-channel neural prosthesis for epidural stimulation.
Proceedings of the IEEE International Symposium on Circuits and Systems, 2016

An implantable wireless multi-channel neural prosthesis for epidural stimulation.
Proceedings of the IEEE International Symposium on Circuits and Systems, 2016

2015
An Implantable Versatile Electrode-Driving ASIC for Chronic Epidural Stimulation in Rats.
IEEE Trans. Biomed. Circuits Syst., 2015

A Summary of Current and New Methods in Velocity Selective Recording (VSR) of Electroneurogram (ENG).
Proceedings of the 2015 IEEE Computer Society Annual Symposium on VLSI, 2015

2014
Improved Signal Processing Methods for Velocity Selective Neural Recording Using Multi-Electrode Cuffs.
IEEE Trans. Biomed. Circuits Syst., 2014

A CMOS Smart Temperature and Humidity Sensor with Combined Readout.
Sensors, 2014

An enhancement to velocity selective discrimination of neural recordings: Extraction of neuronal firing rates.
Proceedings of the 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2014

Fibre-selective discrimination of physiological ENG using velocity selective recording: Report on pilot rat experiments.
Proceedings of the 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2014

2013
Design of an implantable stimulator ASIC with self-adapting supply.
Proceedings of the 2013 IEEE International Symposium on Circuits and Systems (ISCAS2013), 2013

A dedicated electrode driving ASIC for epidural spinal cord stimulation in rats.
Proceedings of the 20th IEEE International Conference on Electronics, 2013

A 1-Wire® communication interface between a control hub and locally powered epidural stimulators.
Proceedings of the 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS), Rotterdam, The Netherlands, October 31, 2013

2012
Active Books: The Design of an Implantable Stimulator That Minimizes Cable Count Using Integrated Circuits Very Close to Electrodes.
IEEE Trans. Biomed. Circuits Syst., 2012

The theory of velocity selective neural recording: a study based on simulation.
Medical Biol. Eng. Comput., 2012

Safety of multi-channel stimulation implants: a single blocking capacitor per channel is not sufficient after single-fault failure.
Medical Biol. Eng. Comput., 2012

Towards a closed-loop transmitter system with integrated class-D amplifier for coupling-insensitive powering of implants.
Proceedings of the 19th IEEE International Conference on Electronics, Circuits and Systems, 2012

A telemetry operated vestibular prosthesis.
Proceedings of the 19th IEEE International Conference on Electronics, Circuits and Systems, 2012

An implantable 3-D vestibular stimulator with neural recording.
Proceedings of the 38th European Solid-State Circuit conference, 2012

A fast passive phase shift keying modulator for inductively coupled implanted medical devices.
Proceedings of the 38th European Solid-State Circuit conference, 2012

Design of a Sacro-lumbar Anterior Root Stimulator Implant for Exercise and Urological Functions.
Proceedings of the BIODEVICES 2012 - Proceedings of the International Conference on Biomedical Electronics and Devices, Vilamoura, Algarve, Portugal, 1, 2012

2011
A Stimulator ASIC Featuring Versatile Management for Vestibular Prostheses.
IEEE Trans. Biomed. Circuits Syst., 2011

An Integrated Stimulator With DC-Isolation and Fine Current Control for Implanted Nerve Tripoles.
IEEE J. Solid State Circuits, 2011

An advanced medical robotic system augmenting healthcare capabilities - robotic nursing assistant.
Proceedings of the IEEE International Conference on Robotics and Automation, 2011

A stimulator ASIC with capability of neural recording during inter-phase delay.
Proceedings of the 37th European Solid-State Circuits Conference, 2011

A summary of the theory of velocity selective neural recording.
Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011

Realization of an active book for multichannel intrathecal root stimulation in spinal cord injury - Preliminary results.
Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011

Fibre-selective recording from peripheral nerves using a multiple-contact cuff: Report on pilot pig experiments.
Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011

2010
High-Power Integrated Stimulator Output Stages With Floating Discharge Over a Wide Voltage Range for Nerve Stimulation.
IEEE Trans. Biomed. Circuits Syst., 2010

Towards an adaptive modified quasi-tripole amplifier configuration for EMG neutralization in neural recording tripoles.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2010), May 30, 2010

A current generator circuit for tripolar stimulation and insensitive to temperature and supply variations.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2010), May 30, 2010

A dual-mode neural stimulator capable of delivering constant current in current-mode and high stimulus charge in semi-voltage-mode.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2010), May 30, 2010

Stimulation management for a multichannel vestibular neural prosthesis.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2010), May 30, 2010

Comparision of methods for interference neutralisation in tripolar nerve recording cuffs.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2010), May 30, 2010

A DC-isolated fine-controlled neural stimulator.
Proceedings of the 36th European Solid-State Circuits Conference, 2010

2008
An Integrated Implantable Stimulator That is Fail-Safe Without Off-Chip Blocking-Capacitors.
IEEE Trans. Biomed. Circuits Syst., 2008

Platinum electrode noise in the ENG spectrum.
Medical Biol. Eng. Comput., 2008

Noise and selectivity of velocity-selective multi-electrode nerve cuffs.
Medical Biol. Eng. Comput., 2008

A programmable ENG amplifier with passive EMG neutralization for FES applications.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2008), 2008

A low-cost laser distance sensor.
Proceedings of the 2008 IEEE International Conference on Robotics and Automation, 2008

2007
Passive Neutralization of Myoelectric Interference From Neural Recording Tripoles.
IEEE Trans. Biomed. Eng., 2007

A Safe Transmission Strategy for Power and Data Recovery in Biomedical Implanted Devices.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2007), 2007

A Fully Integrated Fail-safe Stimulator Output Stage Dedicated to FES Stimulation.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2007), 2007

An ENG Amplifier with Passive EMG Neutralization.
Proceedings of the 14th IEEE International Conference on Electronics, 2007

Recent advances in the design of implantable stimulator output stages.
Proceedings of the 18th European Conference on Circuit Theory and Design, 2007

2006
A stimulator output stage with capacitor reduction and failure-checking techniques.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2006), 2006

Comparison of Transconductance Reduction Techniques for the Design of a Very Large Time-Constant CMOS Integrator.
Proceedings of the 13th IEEE International Conference on Electronics, 2006

Velocity-Selective Recording from Frog Nerve Using a Multi-Contact Cuff Electrode.
Proceedings of the 28th International Conference of the IEEE Engineering in Medicine and Biology Society, 2006

A Miniaturized, Power-Efficent Stimulator Output Stage Based on the Bridge Rectifier Circuit.
Proceedings of the IEEE Asia Pacific Conference on Circuits and Systems 2006, 2006

2005
On cuff imbalance and tripolar ENG amplifier configurations.
IEEE Trans. Biomed. Eng., 2005

Noise from implantable Cooper cable.
Medical Biol. Eng. Comput., 2005

10-channel very low noise ENG amplifier system using CMOS technology.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2005), 2005

A distributed neural signal sensor system.
Proceedings of the International Symposium on Circuits and Systems (ISCAS 2005), 2005

2004
Design of an adaptive interference reduction system for nerve-cuff electrode recording.
IEEE Trans. Circuits Syst. I Regul. Pap., 2004

2003
Design of a low-noise preamplifier for nerve cuff electrode recording.
IEEE J. Solid State Circuits, 2003

2002
Low noise preamplifier design for nerve cuff electrode recording systems.
Proceedings of the 2002 International Symposium on Circuits and Systems, 2002

2001
Adaptive interference reduction in nerve cuff electrode recordings.
Proceedings of the 2001 8th IEEE International Conference on Electronics, 2001

2000
An improved configuration for the reduction of EMG in electrode cuff recordings: a theoretical approach.
IEEE Trans. Biomed. Eng., 2000

The effect of nerve cuff geometry on interference reduction: a study by computer modeling.
IEEE Trans. Biomed. Eng., 2000

1999
Interference reduction in nerve cuff electrode recordings-a new approach.
Proceedings of the 1999 International Symposium on Circuits and Systems, ISCAS 1999, Orlando, Florida, USA, May 30, 1999

Application of closed-loop control in the reduction of interference in nerve cuff recordings.
Proceedings of the 6th IEEE International Conference on Electronics, Circuits and Systems, 1999

1998
Optimal control of ankle joint moment: toward unsupported standing in paraplegia.
IEEE Trans. Autom. Control., 1998


  Loading...