Kian Ann Ng

Orcid: 0000-0002-6044-9841

According to our database1, Kian Ann Ng authored at least 31 papers between 2008 and 2023.

Collaborative distances:
  • Dijkstra number2 of four.
  • Erdős number3 of four.

Timeline

Legend:

Book 
In proceedings 
Article 
PhD thesis 
Dataset
Other 

Links

On csauthors.net:

Bibliography

2023
A 13-bit 70MS/s SAR-Assisted 2-bit/cycle Cyclic ADC with Offset Cancellation and Slack-Borrowing Logic.
Proceedings of the 49th IEEE European Solid State Circuits Conference, 2023

2022
STEER: 3D Printed Guide for Nerve Regrowth Control and Neural Interface in Non-Human Primate Model.
IEEE Trans. Biomed. Eng., 2022

Group-Chopping: An 8-Channel, 0.04% Gain Mismatch, 2.1 µW 0.017 mm<sup>2</sup> Instrumentation Amplifier for Bio-Potential Recording.
IEEE Trans. Biomed. Circuits Syst., 2022

An Ultrasound ASIC With Universal Energy Recycling for >7-m All-Weather Metamorphic Robotic Vision.
IEEE J. Solid State Circuits, 2022

BatDrone: A 9.83M-focal-points/s 7.76µs-Latency Ultrasound Imaging System with On-Chip Per-Voxel RX Beamfocusing for 7m-Range Drone Applications.
Proceedings of the IEEE International Solid-State Circuits Conference, 2022

2021
A One-Shot Learning, Online-Tuning, Closed-Loop Epilepsy Management SoC with 0.97μJ/Classification and 97.8% Vector-Based Sensitivity.
Proceedings of the 2021 Symposium on VLSI Circuits, Kyoto, Japan, June 13-19, 2021, 2021

Body-Coupled Power Transceiver with Node-Specific Body-Area Powering.
Proceedings of the 47th ESSCIRC 2021, 2021

A 7m-range, 4.3mW/Ch. Ultrasound ASIC with Universal Energy Recycling TX for All-Weather Metamorphic Robotic 3D Vision System.
Proceedings of the IEEE Asian Solid-State Circuits Conference, 2021

2020
Erratum to "A 3-Mbps, 802.11g-Based EMG Recording System With Fully Implantable 5-Electrode EMG Acquisition Device".
IEEE Trans. Biomed. Circuits Syst., 2020

A 3-Mbps, 802.11g-Based EMG Recording System With Fully Implantable 5-Electrode EMGxbrk Acquisition Device.
IEEE Trans. Biomed. Circuits Syst., 2020

A 15-Channel Orthogonal Code Chopping Instrumentation Amplifier for Area-Efficient, Low-Mismatch Bio-Signal Acquisition.
IEEE J. Solid State Circuits, 2020

Unveiling Stimulation Secrets of Electrical Excitation of Neural Tissue Using a Circuit Probability Theory.
Frontiers Comput. Neurosci., 2020

2019
A neuro-inspired artificial peripheral nervous system for scalable electronic skins.
Sci. Robotics, 2019

A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip.
IEEE J. Solid State Circuits, 2019

An 8-channel 2.1 μ W0.017 mm<sup>2</sup> 0.04% Gain Mismatch Bio-potential Recording AFE using Group-Chopping Technique.
Proceedings of the IEEE Custom Integrated Circuits Conference, 2019

A 15-Ch. 0.019 mm<sup>2</sup>/Ch. 0.43% Gain Mismatch Orthogonal Code Chopping Instrumentation Amplifier SoC for Bio-Signal Acquisition.
Proceedings of the IEEE Asian Solid-State Circuits Conference, 2019

2018
A power-efficient current-mode neural/muscular stimulator design for peripheral nerve prosthesis.
Int. J. Circuit Theory Appl., 2018

A Fully Wireless Implantable Multi-Channel Muscle Stimulator with Closed-Loop Feedback Control.
Proceedings of the 2018 IEEE Biomedical Circuits and Systems Conference, 2018

2017
A chronic implantable EMG recording system with wireless power and data transfer.
Proceedings of the IEEE Biomedical Circuits and Systems Conference, 2017

Live demonstration: Programmable biphasic multi-channel constant current muscle stimulator with wireless power and data transfer.
Proceedings of the IEEE Biomedical Circuits and Systems Conference, 2017

2016
Implantable neurotechnologies: a review of integrated circuit neural amplifiers.
Medical Biol. Eng. Comput., 2016

A Low-Power, High CMRR Neural Amplifier System Employing CMOS Inverter-Based OTAs With CMFB Through Supply Rails.
IEEE J. Solid State Circuits, 2016

2015
An intrafascicular electrode with integrated amplifiers for peripheral nerve recording.
Proceedings of the 7th International IEEE/EMBS Conference on Neural Engineering, 2015

11.6 A multi-channel neural-recording amplifier system with 90dB CMRR employing CMOS-inverter-based OTAs with CMFB through supply rails in 65nm CMOS.
Proceedings of the 2015 IEEE International Solid-State Circuits Conference, 2015

A 1-V 9.8-ENOB 100-kS/s single-ended SAR ADC with symmetrical DAC switching technique for neural signal acquisition.
Proceedings of the IEEE Asian Solid-State Circuits Conference, 2015

2014
Correlation between muscular and nerve signals responsible for hand grasping in non-human primates.
Proceedings of the 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2014

Neural prosthesis for motor function restoration in upper limb extremity.
Proceedings of the IEEE Biomedical Circuits and Systems Conference, 2014

2013
A Compact, Low Input Capacitance Neural Recording Amplifier.
IEEE Trans. Biomed. Circuits Syst., 2013

2012
A Bionic Neural Link for peripheral nerve repair.
Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2012

A compact, low input capacitance neural recording amplifier with Cin/Gain of 20fF.V/V.
Proceedings of the 2012 IEEE Biomedical Circuits and Systems Conference, 2012

2008
An integrated low power one-pin crystal oscillator.
Proceedings of the IEEE Asia Pacific Conference on Circuits and Systems, 2008


  Loading...