Tom Torfs

Orcid: 0000-0002-1302-3346

According to our database1, Tom Torfs authored at least 31 papers between 2006 and 2022.

Collaborative distances:
  • Dijkstra number2 of four.
  • Erdős number3 of four.

Timeline

Legend:

Book 
In proceedings 
Article 
PhD thesis 
Dataset
Other 

Links

On csauthors.net:

Bibliography

2022
Analysis of Signal Processing Methods to Reject the DC Offset Contribution of Static Reflectors in FMCW Radar-Based Vital Signs Monitoring.
Sensors, 2022

2021
Enabling Robust Radar-Based Localization and Vital Signs Monitoring in Multipath Propagation Environments.
IEEE Trans. Biomed. Eng., 2021

Capacitively-Coupled ECG and Respiration for Sleep-Wake Prediction and Risk Detection in Sleep Apnea Patients.
Sensors, 2021

2-D Localization, Angular Separation and Vital Signs Monitoring Using a SISO FMCW Radar for Smart Long-Term Health Monitoring Environments.
IEEE Internet Things J., 2021

Automatic quality assessment of capacitively-coupled bioimpedance signals for respiratory activity monitoring.
Biomed. Signal Process. Control., 2021

Noncontact Electrophysiology Monitoring Systems for Assessment of Canine-Human Interactions.
Proceedings of the 2021 IEEE Sensors, Sydney, Australia, October 31 - Nov. 3, 2021, 2021

Active capacitive ECG system with all-digital "driven right leg" common mode suppression.
Proceedings of the IEEE Biomedical Circuits and Systems Conference, BioCAS 2021, 2021

2020
Unobtrusive, Through-Clothing ECG and Bioimpedance Monitoring in Sleep Apnea Patients.
Proceedings of the Computing in Cardiology, 2020

2019
A 400 GΩ Input-Impedance Active Electrode for Non-Contact Capacitively Coupled ECG Acquisition With Large Linear-Input-Range and High CM-Interference-Tolerance.
IEEE Trans. Biomed. Circuits Syst., 2019

A680 μW Burst-Chirp UWB Radar Transceiver for Vital Signs and Occupancy Sensing up to 15m Distance.
Proceedings of the IEEE International Solid- State Circuits Conference, 2019

Capacitive multi-electrode array with real-time electrode selection for unobtrusive ECG & BIOZ monitoring.
Proceedings of the 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2019

Data Quality Assessment of Capacitively-Coupled ECG Signals.
Proceedings of the 46th Computing in Cardiology, 2019

2018
Systolic Time Interval Estimation Using Continuous Wave Radar With On-Body Antennas.
IEEE J. Biomed. Health Informatics, 2018

A Direct Phase-Tracking Doppler Radar Using Wavelet Independent Component Analysis for Non-Contact Respiratory and Heart Rate Monitoring.
IEEE Trans. Biomed. Circuits Syst., 2018

Evaluation of a Multichannel Non-Contact ECG System and Signal Quality Algorithms for Sleep Apnea Detection and Monitoring.
Sensors, 2018

Sensor Fusion of Capacitively Coupled ECG and Continuous-Wave Doppler Radar for Improved Unobtrusive Heart Rate Measurements.
IEEE J. Emerg. Sel. Topics Circuits Syst., 2018

A 400GΩ Input-Impedance, 220MVpp Linear-Input-Range, 2.8Vpp CM-Interference-Tolerant Active Electrode for Non-Contact Capacitively Coupled ECG Acquisition.
Proceedings of the 2018 IEEE Symposium on VLSI Circuits, 2018

2017
Frequency-Tracking CW Doppler Radar Solving Small-Angle Approximation and Null Point Issues in Non-Contact Vital Signs Monitoring.
IEEE Trans. Biomed. Circuits Syst., 2017

2016
Robust wireless capacitive ECG system with adaptive signal quality and motion artifact reduction.
Proceedings of the 2016 IEEE International Symposium on Medical Measurements and Applications, 2016

2015
A 345 µW Multi-Sensor Biomedical SoC With Bio-Impedance, 3-Channel ECG, Motion Artifact Reduction, and Integrated DSP.
IEEE J. Solid State Circuits, 2015

2014
Noncontact ECG Recording System With Real Time Capacitance Measurement for Motion Artifact Reduction.
IEEE Trans. Biomed. Circuits Syst., 2014

18.3 A multi-parameter signal-acquisition SoC for connected personal health applications.
Proceedings of the 2014 IEEE International Conference on Solid-State Circuits Conference, 2014

2013
Non-contact ECG recording system with real time capacitance measurement for motion artifact reduction.
Proceedings of the 2013 IEEE Biomedical Circuits and Systems Conference (BioCAS), Rotterdam, The Netherlands, October 31, 2013

2012
Wireless 3-lead ECG system with on-board digital signal processing for ambulatory monitoring.
Proceedings of the 2012 IEEE Biomedical Circuits and Systems Conference, 2012

2011
Two-Dimensional Multi-Channel Neural Probes With Electronic Depth Control.
IEEE Trans. Biomed. Circuits Syst., 2011

A 30 μ W Analog Signal Processor ASIC for Portable Biopotential Signal Monitoring.
IEEE J. Solid State Circuits, 2011

Ultra-Thin Chip Package (UTCP) and stretchable circuit technologies for wearable ECG system.
Proceedings of the 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 2011

2010
A 30µW Analog Signal Processor ASIC for biomedical signal monitoring.
Proceedings of the IEEE International Solid-State Circuits Conference, 2010

2009
Ultra-low-power biopotential interfaces and their applications in wearable and implantable systems.
Microelectron. J., 2009

P300 Detection Based on Feature Extraction in On-line Brain-Computer Interface.
Proceedings of the KI 2009: Advances in Artificial Intelligence, 2009

2006
Technologies for highly miniaturized autonomous sensor networks.
Microelectron. J., 2006


  Loading...